Skip to main content

Development of Indirect Competitive Enzyme-Linked Immunosorbent Assay and Lateral-Flow Immunochromatographic Strip for the Detection of Digoxin in Human Blood.

The mice hybridoma cell lines producing a stable, highly specific monoclonal antibody with good affinity for cardiac glycoside digoxin (DIG) was established to develop enzyme-linked immunosorbent assay, indirect and lateral-flow immunochromatographic strips to detect the DIG in human blood. The DIG hapten was coupled to bovine serum albumin or ovalbumin chicken with sodium periodate oxidation. 

The highest sensitivity and specificity Equine Serum of the antibody had a median inhibitory concentration (IC50) of 0.45 ng / mL, a wide range of linear detection of 0.293 to 0.7 ng / mL, and low cross-reactivity with some analog DIG. Cut-off value of lateral flow immunochromatographic strip is 5 ng / mL when the strip tested with human blood. The immunochromatographic lateral flow test strips provide a quick and convenient method for determining the DIG in the plasma that can be observed visually only 5 minutes to promote rational drug use.


Haemato-biochemical changes and the prevalence of parasitic infection native chickens sold in the market Kiambu County, Kenya.


This study aimed to determine the p
revalence of parasites and haemato-biochemical changes that may occur from the possibility of parasite infection in indigenous chickens sold in Kiambu County, Kenya. Thirty adult chicken purchased and examined for ectoparasites, haemoparasites and haemato-biochemical changes. Post mortem carried out to restore the gastro-intestinal parasites and fecal samples were taken for the number of eggs / oocysts. 

Forty-seven percent (14/30) examined chickens were in poor body condition, 43% (13/30) in the fair and 10% (3/30) in good body condition. ectoparasites infection prevalence was 66.7% (20/30). Four haemoparasites isolated. Overall worm prevalence was 86.6% (26/30), nematodes in 76.7% (23/30) and cestodes in 40% (12/30). After the processing of stool samples, 30% (9/30) were positive for ova and 30% (9/30) had coccidia oocysts.

 In connection with the normal value, the total number of erythrocytes is low and leukocyte counts with a high number of cells Band. Average Equine Serum Albumin hematocrit and heterophil high values ​​(p = 0.0005; p = 0.0061). Average low lymphocyte count (p = 0.0128) in chickens with ectoparasites infestation. Eosinophils increased significantly (p = 0.0363) although the average erythrocyte number decreased (p = 0.0176), the chicken with gastrointestinal parasites. 

Creatine phosphokinase and high blood glucose levels, serum protein and albumin levels were low. blood glucose levels decreased significantly (p = 0.0239) and total plasma protein increased (p = 0.045) in chickens with Haemoproteus spp. infection.

Comments

Popular posts from this blog

Highly specific detection of myostatin prodomain by an immunoradiometric sandwich assay in serum of healthy individuals and patients.

BACKGROUND Myostatin is a factor derived muscle that functions as a negative regulator of skeletal muscle growth. Induction of myostatin expression was observed in mouse models of muscle wasting and in patients with cancer skinny or lung disease. Therefore, there is an increasing interest for use as a biomarker in serum myostatin. METHOD We established sandwich immunoradiometric assay (IRMA), which uses a chicken polyclonal, affinity purified antibodies directed  G.Pig Serum against a commercially available human myostatin prodomain. We determined the serum concentrations of myostatin prodomain in 249 healthy individuals and 169 patients with heart failure, 53 patients with cancer and 44 patients with chronic lung disease. RESULTS The IRMA has a detection limit of 0.7ng / ml, an inaccuracy intraassay of ≤14.1% and interassay imprecision of ≤ 18.9%. The specificity of our assay demonstrated by size exclusion chromatography, the detection of myostatin by Western-blotting and Smad-de...

Clonal Progression during the T Cell-Dependent B Cell Antibody Response Depends on the Immunoglobulin DH Gene Segment Repertoire.

The diversity of complementarity determining region of one third of the IgH chain immunoglobulin limited by natural selection diversity (DH) sequence. To test the functional significance of this problem in the context of the response (TD) thymus dependent immunity, we immunized BALB / c mice with WT or modified sequence with a 2-phenyloxazolone DH-plus chicken serum albumin (Phox-CSA).  We chose this antigen for the Goat Plasma study of humoral immune responses against the hapten Phox role in the development of the current theoretical framework which our understanding of the driving forces TD response is based. To allow for direct comparison, we use the classical approach produces monoclonal Ab (mAb) of the various stages of the immune response to Phox to assess the effect of changing the sequence DH clonal expansion, class switching and affinity maturation, the advantages of TD responses.  Compared with WT, strain-induced TD humoral IgM and IgG antibody production in-DμFS ΔD ...

Bio-efficacy comparison of herbal-methionine and DL-methionine based on performance and blood parameters of broiler chickens.

This study was conducted to compare the bio-efficacy of herbal methionine (D-Met) relative to DL-methionine (DL-Met) at 160 "Ross 308" broiler chickens. DL-Met and H-Met added to the basal diet in eight experimental treatments with three and four concentrations of each in starter, grower and finisher period. blood parameters were measured at 24 and 42 days of age consists of: serum protein (total protein, albumin and globulin), serum  Feline Serum Albumin uric acid, serum fatty (low density lipoprotein, density lipoprotein high triglycerides and cholesterol) and serum enzyme (alanine amino transaminase and aspartate amino transaminase).  Completely randomized design, multi-exponential regression and multilinear used to determine the bio-efficacy of H-Met in terms of performance and blood parameters of broiler. The results showed that supplementation of methionine (Met) source had no significant effect on blood parameters at 24 days of age. At 42 days of age and serum globulin...